Our product range includes a wide range of cpap auto bipap machine, f&p airvo 2 hfnc monthly rental in hyderabad, f&p humidifier mr 850 refurb, portable transport ventilator for adults & pediatric patients - ambulance and invasive and non invasive ventilator.
₹ 30000 Get Latest Price
Machine Type | BiPAP with Humidifier |
Brand | BMC Medical |
Service Location | Habsiguda, Hyderabad |
BMC, White color | 1.5 kg, 30 inch, S ,T,S/T, CPAP modes with integrated humidifier |
Minimum order quantity: 1 Piece
Brand: BMC
Country of Origin: China
Model Name/Number: BMC G2S B30VT
Altitude Compensation: Fully Automatic
Weight: 1.2 KG
Warranty: 1 Year
Pressure Range: 4-30cm H20
Auto on/off: Yes
Device type : Bi-level S/T with target tidal volume
₹ 30000 Get Latest Price
Brand | Fisher & Paykel |
Patient Type | Neonatal |
Connector | Yes |
Relative Humidity | 100% |
Flow Rate | 80 L/ min |
Operation Mode | Manual |
Minimum order quantity: 1 Piece
₹ 50000 Get Latest Price
Brand | Fisher & Paykel |
Patient Type | Neonatal |
Connector | Yes |
Relative Humidity | 100% |
Flow Rate | 80 L/ min |
Heater Plate Thermal Cutout | 45 |
Operation Mode | Automatic |
Minimum order quantity: 1 Piece
Temperature and flow probes provide information to the humidifier that adjusts its power output to the heater plate and circuits to ensure humidity delivery is optimized for different conditions.
₹ 440000 Get Latest Price
Display Type | LCD |
Brand | breas |
Model Name/Number | vivo 45 LS |
Patient Type | Adult, Paediatric |
Packaging Type | Box |
ntilation Modes |
PSV, PSV-AE, PSV(TgV), PSV(TgV)-AE, PCV, PCV-AE, PCV(TgV), PCV(TgV)-AE, PCV(A), PCV(A)-AE, PCV(A+TgV), PCV(A+TgV)-AE, CPAP, VCV, VCV(A), VCV-MPV, VCV-SIMV, PCV-SIMV, PCV-MPV |
Patient Modes |
Adult, Paediatric |
Device Modes |
Home, Clinical |
Profiles |
3 settable profiles |
Inspiratory Pressure |
4 – 50 cmH2O |
PEEP |
2 cmH2O to 20 cmH2O |
Breath Rate/Back-up Rate |
Adults: 4 – 40 bpm, Paediatrics: 6 – 60 bpm |
Inspiratory Trigger |
1 – 9 |
Inspiratory Time |
0.3 – 5 s |
Backup Inspiratory Time |
0.3 – 5 s (PSV) |
Rise Time |
1 – 9 (PSV & PCV), 50 – 90%, Off (VCV) |
Inspiratory Trigger |
1 – 9 (PSV & PCV, VCV), Off (PCV, VCV) |
Expiratory Trigger |
1 – 9 (PSV, PCV-SIMV, VCV-SIMV) |
Minimum Inspiratory Time |
Off, 0.3 to 3 s |
Maximum Inspiratory Time |
0.3 to 5 s, Off |
Tidal/Target Volume |
Adults: 300 – 2000 ml, Paediatrics: 50 – 500 ml |
Auto-EPAP |
On/Off, Min/Max EPAP: 2 − 20 cmH2O, PS: 2 – 50 cmH2O −Max EPAP, EPAP Step: 0.5 − 2 cmH2O, Relax Time: 120 − 720 sec/Off, Min PS/Max PS: 2 – 50 cmH2O -Max EPAP, Pressure Limit: Max EPAP +2 cmH2O – 50 cmH2O |
Displayed data |
Ppeak, PEEP, Pmean, Leakage, MV, Vt, FiO2, % in TgV, Total Rate, Spont Rate, % spont, SpO2, Pulse, Rate, I:E, Inspiratory time, Rise time, EtCO2, PtcCO2, AHI |
Waveforms |
Pressure, flow, volume, EtCO2, Effort Belts |
Trends over 1, 6, 24, 48 h and 10 days on device screen |
Ppeak, PEEP, Total rate, Spont rate, Vt, Leakage, SpO2, EtCO2 |
POWER SUPPLIES |
|
Mains supply |
100 to 240 V AC |
External DC |
24 V |
Click-in battery |
6.5 hours |
Internal battery |
2.5 hours |
|
|
s |
₹ 470000 Get Latest Price
Tidal Volume | 50 ml |
Respiratory Rate | 200 |
Requirement Type | New |
Brand | RESMED |
Model Name/Number | Astral 150 |
Ventilation Modes | invasive & non invasive |
RSBI (Rapid Shallow Breathing Index) | 600 |
Patient Age Group | Paediatric, Adult |
Peak Airway Pressure | 60 |
Plateau (%) | 60 |
Gangaprasad K (CEO)
ALS Medical Technologies
1st Floor, 1-4-63/2, Plot No.43, Street No.8, Sneha Nagar Colony, Habsiguda, Secunderabad
Hyderabad - 500008, Telangana, India